ATLASense™ Semi-Custom Monitoring Instrumentation
Selection chart
Parameter Definitions
ECG |
Electrocardiogram (cardiac activity) waveform |
ECG-HR |
ECG derived digital heart rate |
PPG |
Photo-plethysmogram, finger, blood volume pulse-waveform |
PPG-HR |
Photo-plethysmogram, finger, derived digital heart rate |
PPG- R |
Photo-plethysmogram, finger, derived respiration waveform |
GSR |
Galvanic skin resistance waveform |
ASR™ |
Auto-zero baseline skin response, high sensitivity GSR waveform |
SCR |
Skin conductance response waveform |
SPR |
Skin potential response waveform |
RESP-B |
Respiration waveform, diagonal piezoelectric sensor strap. |
RESP-S |
Respiration waveform, seat embedded piezoelectric sensor |
TEMP |
Skin temperature, finger, digital and waveform |
EEG |
Electroencephalogram (brainwaves), waveform |
EOG |
Electrooculogram (eye movement), waveform |
EMG |
Electromyogram (neuromuscular activity), waveform |
SWAY |
Whole body movement patters, waveform |
ACC |
Limb acceleration waveform |
ACC-P |
Acceleration derived limb position |
PRESS |
Tactile pressure waveform |
BIOAMP1 |
Custom-configuration bio-amplifier |
BIOAMP2 |
Custom-configuration high input impedance electrometer bio-amplifier |
BIOSTIM |
Custom-configuration Skin Stimulator |
PTT |
Pulse transit time (ECG “R” wave to peripheral pulse peak delay time) |
AR800W Wireless Bluetooth, compact, wearable, ambulatory |
Example ECG configurations
Real-time PC display and recording of exercise ECG
Model |
Description |
Features |
FOB Price ($US) |
|
| AR800-1L-ECG |
One lead wireless PC ECG 0.5-40Hz, 500samples/sec., 2000 mV/mV |
Wireless Bluetooth, compact, wearable, ambulatory, 12 bit resolution. |
1900 |
|
AR800-3L-ECG |
Three lead wireless PC ECG 0.5-40Hz, 250 samples/sec., 2000 mV/mV |
Same as above |
2700 |
|
AR800-6L-ECG |
Six lead wireless PC ECG 0.5-40Hz, 250 samples/sec., 2000 mV/mV |
Same as above |
2900 |
|
AR800-12L-ECG |
Twelve lead wireless PC ECG 0.5-40Hz, 250 samples/sec., 2000 mV/mV |
Same as above |
4700 |
|
Example MD configuration
Real-time PC display and recording of ANS & CNS parameters
Model |
Description |
Features |
FOB Price ($US) |
|
| AR800-AC7 |
- ECG, One lead 0.5-40Hz, 500 samples/sec., 2000 mV/mV
- GSR, 50 samples/sec
- ASR™, 50 samples/sec
- TEMP, 50 samples/sec
- RESP, 50 samples/sec
- EMG, surface, integrated, 4 samples/sec
- EEG, 1.5-30Hz, 500 samples/sec., 2500 uV/uV
|
Wireless Bluetooth, compact, wearable, ambulatory, 12 bit resolution. |
4300 |
|
Example stress management/mental preparation coaching configuration
Real-time PC display and recording of ANS parameters
Model |
Description |
Features |
FOB Price
($US) |
|
| AR800-A8 |
- ECG, One lead 0.5-40Hz, 500 samples/sec., 2000 mV/mV
- ECG HR
- GSR, 50 samples/sec
- ASR™, 50 samples/sec
- SCR, 50 samples/sec
- TEMP, 50 samples/sec
- RESP, 50 samples/sec
- PPG, 50 samples/sec
|
Wireless Bluetooth, compact, wearable, ambulatory, 12 bit resolution. |
4300 |
|
Example neurofeedback configuration (less neurofeedback PC software)
Real-time PC display and recording of dual channel EEG parameters
Model |
Description |
Features |
FOB Price
($US) |
|
| AR800-EE2 |
Dual channel EEG, 1.5-30Hz, 500 samples/sec., 2500 uV/uV |
Wireless Bluetooth, compact, wearable, ambulatory, 12 bit resolution. |
2300 |
|
Example physical medicine configuration
Real-time PC display and recording of neuromuscular parameters
Model |
Description |
Features |
FOB Price
($US) |
|
| AR800-EM2 |
2 channels EMG, surface, integrated, 4 samples/sec |
Wireless Bluetooth, compact, wearable, ambulatory, 12 bit resolution. |
2300 |
|
| AR800-EMS2 |
- Dual channel EMG, surface, integrated, 4 samples/sec
- Dual channel skin stimulator
|
Wireless Bluetooth, compact, wearable, ambulatory, 12 bit resolution. |
2900 |
|
Example sleep/mental workload configuration
Real-time display and recording
Model |
Description |
Features |
FOB Price
($US) |
|
| AR800-AC8 |
- RESP, 50 samples/sec
- Dual channel EMG, surface, integrated, 4 samples/sec
- Dual channel EEG, 1.5-30Hz, 500 samples/sec., 2500 uV/uV
- Three channel triaxial limb acceleration
|
Wireless Bluetooth, compact, wearable, ambulatory, 12 bit resolution. |
4400 |
|
Example general biofeedback practitioner configuration
Real-time PC display and recording of ANS & CNS parameters
Model |
Description |
Features |
FOB Price
($US) |
|
| AR800-AC6 |
- GSR, 50 samples/sec
- ASR™, 50 samples/sec
- TEMP, 50 samples/sec
- PPG-R (Resp), 50 samples/sec
- PPG HR
- EMG, surface, integrated, 4 samples/sec
|
Wireless Bluetooth, compact, wearable, ambulatory, 12 bit resolution. |
3900 |
|
Example driving simulator configuration
Real-time PC display, recording and testing driver vigilance
Model |
Description |
Features |
FOB Price
($US) |
|
| AR800-NOVACORDER™ |
- Dual channel EMG, surface, integrated, 4 samples/sec
- Dual channel EEG, 1.5-30Hz, 250 samples/sec., 5000 uV/uV
- Dual channel EOG, 1.5-30Hz, 250 samples/sec., 5000 uV/uV
- ECG, One lead 0.5-40Hz, 500 samples/sec., 1000 mV/mV
- ECG HR
- Dual channel PRESS (Grip Pressure), 50 samples/sec.,
- PVT skin stimulator
|
Wireless Bluetooth, compact, wearable, ambulatory, 16 bit resolution. |
7500 |
|
AR400 4-channel isolated analog EMG |
Example physical medicine configuration
Real-time PC display and recording of neuromuscular parameters
Model |
Description |
Features |
FOB Price
($US) |
|
| AR400 |
4 channels isolated analog EMG, surface, raw, 6 gain positions up to 100,000, 3 choices of HP and LP filters Isolation to IEC-601-1 |
Compact, stackable.
|
4500 |
|
ATLASense™ AR800W Series
Leading-edge wireless, wearable bio-monitor |
General Description
The ATLASense™ AR800W wireless monitoring series is another Atlas world-class first. The AR800W bio-monitoring platform offers rapidly configurable solutions to professionals and OEMs requiring PC-based biophysical data acquisition and display.
With comprehensive choice of multi-channel, configurable parameters, the leading-edge technology device delivers outstanding signal quality and user-friendly operation for a broad variety of applications. |
The unique AR800W features, capabilities and comprehensive building block modular design represent a unique breakthrough, outperforming devices costing much more and opening the boundaries of ambulatory monitoring.
The AR800W series draws on our 30-year monitoring experience. It is the sequel to the FDA-regulated ATLAS AR1, AR3510, AR3510D and AR3520, and to the Standards Institute of Israel safety/EMC compliant ATLAS AR7000 (USB and fiber optics PC-connectivity series). |
Features
- High performance signal sensing, processing and communicating
- Wearable, wireless real-time monitoring
- Unobtrusive, compact, robust and lightweight
- Clips to arm or waist straps
- Analog-to-digital resolution mix of 12, 16 and 24 bits
|
Key Benefits
- Best-value in its class
- Operates on standard 2 AA batteries
- User friendly and affordable
- Open architecture for 3rd party software
- Reliable wireless radio Bluetooth to PC or PDA
- Up to 8 devices with jam-free transmission
- 10 meters range 30, 1000 meters options
- Absolute safety
- Wireless software upgrade
|
Broad Monitoring Applications
The AR800W series is the ideal choice for broad wireless monitoring applications, including: Medical diagnostic device platform; Tele-diagnostics; Medical and psychophysiological education and research; Polygraphy; Interactive feedback therapy; Sleep studies; Performance studies; Vital signs; Psychomotor vigilance tests; Emotional response; Biometrics; |
Alertness & drowsiness; Mental workload; Bio-control; Remote-controlled stimulation; Physical rehabilitation; Stress management; Treatment and medication efficacy; Unattended worker safety; Coaching; Biomedical projects; Fitness; Wellness; Mental preparation; Peak performance training. |
Comprehensive Parameter Options
The AR800W series enables measuring and deriving a broad range of parameters, including: ECG; EEG; EOG; EMG; Respiration; Temperature; Heart rate; PPG (Photoplethysmography); |
GSR; ASR™ (Atlas auto-baseline GSR); SCR; SPR (skin potential response); Activity; Blood volume wave; Body acceleration and position; PTT (Pulse transit time); Remote-programmed stimulation; Weight; Force. |
|
AR2000A |
AR4000MKR |
AR7000 |
AR900W |
AR100 |
|

|

|
|
|

|
Basic model description |
6-channel posturograph |
14-channel smart seat |
16-channel general-purpose platform |
Dual channel, wireless, PC-controlled skin stimulator |
All-in-one standalone monitor |
Safety-
Data Isolation |
Non-isolated |
Wireless radio Bluetooth |
Optical isolation to IEC-601-1 |
|
N/A |
Safety-
Power Isolation |
Non-isolated |
Rechargeable battery pack |
Magnetic USB isolation to IEC-601-1 |
|
N/A |
Analog-to-Digital resolution and max. channels |
16 bits, 6 channels |
16 bits 16 channels |
16 bits 16 channels, plus 12 bits 8 channels |
|
N/A |
Standard channels
|
2 static posture channels, 2 dynamic posture channels, 2 vector channels |
ECG, heart rate, BP changes via PTT (pulse transit time), talking, 2 channels each: ASR™, pulse, respiration, motion. |
Pulse, respiration, EMG, ECG, EEG, EOG, GSR, ASR*, PTT |
|
EMG, GSR, ASR™, HR, TEMP |
|