The BioGraph Infiniti DynaMap Suite, combined with any of four Thought Technology encoders; FlexComp Infiniti, ProComp Infiniti, ProComp+, or ProComp2, lets you record, replay and review 2-10 channel SEMG monitoring and biofeedback sessions. Over 100 screens display SEMG readings combined with other physiological signals. A key feature is live video, which enhances the review of data enabling one to view the video display while pinpointing a moment in time for statistics for each measure. Dual monitor screens also play a key role in the software, allowing the client to view what is required for feedback and the clinician to view the actual data. The BioGraph Infiniti software also lets you edit the existing screens and create new ones of your own.
DynaMap for the FlexComp Infiniti provides 7 channel sets and 57 screens for high resolution and accurate multi-channel SEMG data-acquisition.
The 7 channel sets allows you several choices: connect up to 10 MyoScan-Flex sensors for raw SEMG recording, a combination of 6 MyoScan-Flex Sensors and 4 Goniometers, 6 MyoScan and 2 Goniometers, 6 MyoScan with 2 Force Sensors, 10 Force Sensors, 10 Goniometers, 2 MyoScan-Flex with EKG, Temperature and Skin Conductance for SEMG and peripheral biofeedback. On-board Compact Flash memory gives you the capability to save data directly to the encoder for real life assessments away from the office or lab.
Left is a two channel recording screen, for observing the interplay of median frequency and RMS data between two bilateral sites. All median frequency (MF) statistics are based on smoothed MF to provide a smoothed view of this measure.
DynaMap for the ProComp Infiniti includes 7 channel sets and 48 screens for multi-channel raw and RMS SEMG combined with up to 6 other physiological measures.
Screens include exciting new 3-D graphics of animated figures that work with the client. As the client moves the animation moves! In addition there are screens to look at the interplay of median frequency and RMS data between bilateral sites. The raw EMG signals can be displayed raw or, as RMS in line graphs and bar graphs as well as 2-D and 3-D spectral displays synchronized with video.
This screen shows two channels of RMS data derived from channels A and B raw inputs to the ProComp Infiniti shown in a multi line graph and 3D power spectrum displays.
DynaMap for the ProComp+ encoder includes 7 channel sets and 37 screens for 8-channels of SEMG or a mix of 2 channels of SEMG with up to 6 other physiological measures.
Build your own screens using one of our comprehensive channel sets, which includes physical and virtual (including statistics) channels or use the Developer Tools to make changes to the existing channel set to meet your needs. Each of the 7 different channel sets allows for a different use of the ProComp+.
This screen is for bilateral comparison of para-spinal muscle activity, divided into four pairs of SEMG sensors at C7–T1, T6–T7, T12–L1 and L2–L3. When the difference in SEMG between any pair is greater than 20% a light turns red. Animated bars and digital displays show RMS SEMG of each muscle.
DynaMap for the ProComp2 includes 4 channel sets and 15 screens for 1 and 2-channel SEMG applications. It allows you to select from four different sensor combinations for the ProComp2 to use SEMG or either a force sensor, goniometer or torsiometer.
For example, choose a channel set for 2 MyoScan-Pro sensors for SEMG and load a screen to display RMS muscle activity at muscle pairs during movement. A difference greater than 20% between muscle pairs is indicated by the light turning red. Video enables viewing of the motion performed at the same time!
Thought Technology Computerized Biofeedback Systems
Thought Technology is pleased to provide our customers with the Infiniti series of hardware, software and Suite packages. They have been designed to maximize your investment. Simply add sensor modules, and you are ready to go.
The Suites are a grouping of channel sets, screens and scripts created to make the most of the encoder for which it was designed. Some Suites, such as DynaMap, are designed to include all encoder types and include channel sets, screens and scripts with specific designs for each encoder.
Note: All Procomp and Flexcomp systems will include the Physiology Suite.
To substitute the EEG Suite
To order the systems with both the Physiology and EEG suites
$275 Extra
EEG module
$275
EEG module with Impedance Testing
$385
EMG module
$385
GSR module
$275
Temperature module
$200
Respiration module
$275
Heart Rate/BVP module
$275
EKG module
$275
Physiology Suite
$275
EEG Suite
$275
2-Channel Connectivity EEG Cable
$140
BioGraph Infiniti version 4.0 upgrade to your current Biograph Infiniti
$150
EEG Suite or Physiology Suite with BioGraph Infiniti version 4.0 upgrade
$325
BioGraph® Infiniti 4.0 Platform
The BioGraph Infiniti software is
the core for all current and future Thought Technology
Biofeedback and Psychophysiology products. It includes
all the features and functions required to run the
Suites as well as to create your own customized screens
and scripts using the Developer Tools.
Gain total control over your
feedback environment with the BioGraph Infiniti
Developer Tools.
With powerful editing
capabilities, you can easily create new channel sets,
rapidly design customized display screens and develop
automated session scripts that can significantly expand
your biofeedback and data-acquisition
horizons!
EEG Suite (New) The EEG Suite 4.0 includes
new Z-Score training screens and new coherence training
screens with dual-threshold range training. It
offers over 80 display screens for many standard
EEG protocols, including an outstanding
alpha-theta training screen and a number of
template-style screens for training with 3, 6 or
10 user-defined EEG bands. The standard
protocols can be used for training alpha
amplitude (range), alpha peak frequency, alpha
theta, beta amplitude, SMR amplitude, theta
beta, theta SMR and wide band inhibit.
Z-Score Biofeedback Add-on for EEG Suite (New) Provides real-time
comparisons of 2-channel EEG to NeuroGuide’s
normative database. Metrics include coherence,
phase, amplitude asymmetry, relative power,
absolute power and power ratios for eight
different frequency bands.
Physiology™ Suite (NEW)
The Physiology Suite 4.0
includes new screens for Programmable
Respiration Pacer, new screens for Heart Rate
Variability (HRV) Resonant Frequency Detection
and NN50 & pNN50, as well as new screens for
pulse transit time feedback (delay between EKG
R-spike and finger pulse). It provides all the
tools you need for multi-modality physiological
assessments and over 80 display screens for
training with standard physiological sensors
including heart rate with EKG or blood volume
pulse (BVP), electromyography (EMG), skin
conductance, temperature and respiration.
Rehab™ Suite
The Rehab Suite for MyoTrac Infiniti Clinical combines
Thought Technology's powerful BioGraph Infiniti software with
specialized protocols, tutorials, screens, animations and
statistics, designed to provide customized clinical treatment for
your clients. Its flexibility in all aspects of its use, from
recording options to protocols and sound and visual feedback, will
enable you to reach new levels of treatment.
Continence™ Suite
The Continence Suite for MyoTrac-Infiniti
U-Control
Clinical combines Thought Technology's powerful BioGraph Infiniti
software with specialized protocols, tutorials, screens, animations
and statistics, designed to provide customized clinical treatment
for your clients. Its flexibility in all aspects of its use, from
recording options to protocols and sound and visual feedback, will
enable you to reach new levels of treatment.
Ergonomics™ Suite The Ergonomics Suite has been designed for Ergonomic
applications including screens for Force, Dual Axis Goniometers, 2
Single Axis Finger Goniometers and/or Single Axis Torsiometers for
measuring rotation in one direction. The Suite is designed to be
used on ProComp Infiniti, FlexComp Infiniti and ProComp2 systems
systems which support BioGraph Infiniti software with channels sets
to maximize the features of each.
DynaMAP™ Suite The DynaMap Suite is focused on SEMG with a wide variety of
different applications for muscle re-education and relaxation. It
also incorporates other modalities, including Goniometer and Force,
in some of the channel sets and screens. The Suite is designed to be
used on ProComp Infiniti, FlexComp Infiniti and ProComp2 systems
which support BioGraph Infiniti software with channels sets to
maximize the features of each.
BioGraph®-X Infiniti 1 & 2
(a
variety of animations)
BioGraph-X Infiniti CD 1 (83 animations) and CD 2 (55
animations) are the first in a series of animation CD’s to be
offered by Thought Technology to enhance your training sessions. The
CD’s are compiled of a variety of animations from nature, to
fractals and games.
CardioPro 2.0™ CardioPro is a specialized
biofeedback application that provides a sophisticated array of
feedback tools for monitoring HRV and Respiratory Sinus Arrhythmia
(RSA). Requires a ProSB if used with Infiniti
hardware.
New PLAY ATTENTION Edufeedback system - for Attention, Focus, Concentration, Active and Short Term Memory, Hyperactivity Reduction, Reading Comprehension - uses the same feedback science and technology perfected for NASA astronauts and US Air Force pilots. Time payment plan options available. More Info...
Desiccants - Mol Sieve, Silica Gel - Excellent Quality and Lowest Prices on Quantity Purchases. More info...