WaveRider Jr.

 

Home

 

Products (A-H)

 

Products (I-Z)

  Registration Desk   Contact Us
View Cart   |  Checkout
 

 
     
 
SEARCH THE SITE
 
   
     
   
     
   
     
   
     
   
     
   
     
   
     
   
     
   
     
   
     
   
     
   
     
   
     
   
     
   
     
   
     
   
     
   
     
   
     
   
     
   
     
   
     
   
     
   
     
     
     

WaveRider Jr.

Converts Brain, Heart, Muscle, and GSR signals into Music, Tones, Graphs, Bars, and Data. Includes Hardware, Software, and Accessories.

WaveRider Jr. 60 hertz Price: $950.00 Add to Cart | View Cart | Checkout

WaveRider Jr. 50 hertz Price: $950.00 Add to Cart | View Cart | Checkout

Detailed Description

WAVERIDER 2cx* HARDWARE

  • TWO LOW NOISE CHANNELS READ BRAIN, HEART, OR MUSCLE SIGNALS ONE DEDICATED GSR CHANNEL READS SKIN RESISTANCE CONNECTS TO SERIAL PORT OF COMPUTER BATTERY OPERATED
  • OPTICALLY ISOLATED

WaveWare:  WaveRider Windows Software Works with WinXP; requires XP mode to run in Windows 7

  • RUNS UNDER WIN 95, 98, 2000, XP, VISTA EASY TO USE 150 PAGE ILLUSTRATED MANUAL COMES WITH PRE-PROGRAMMED PROTOCOLS THAT ADDRESS MOST USERS'S NEEDS QUICKLY DESIGN COMPLEX CUSTOM PROTOCOLS
  • EXPORT PROCESSED DATA TO SPREADSHEET FOR FURTHER ANALYSIS
  • SOUND VARIABLES INCLUDE NOTES, SCALES, PITCH, KEY, VOLUME, AND INSTRUMENT CHOICE VISUAL OUTPUTS INCLUDE BARS, GRAPHS, SPECTROGRAM, AND METERS FEEDBACK MODES INCLUDE CONDITIONAL, PROPORTIONAL, CONDITIONAL/PROPORTIONAL, DOMINANT FREQUENCY, AND COHERENCE HEART, MUSCLE, GSR
  • FREQUENCY ANALYSIS ENGINES INCLUDE BOTH FFTS AND DIGITAL FILTERS
  • ONE YEAR WARRANTY

*formerly WaveRider jr.

/productimages/Neurofeedback WaveRider 2cx.jpg


Two low-noise multi-modality channels read brain, heart, or muscle signals. A single dedicated GSR channel reads skin resistance.

Outputs include music, tones, graphs, bars, and spectrogram, as well as raw and processed data. Comes with many popular protocols for easy start-up. Point-and-click programmability means quick development of complex custom protocols .


Includes: WaveRider Pro hardware (pictured above), WaveWare Software, two sets of two head electrodes, set of two ear electrodes, Ten20 paste, NuPrep gel, Serial Cable, three jumper cables, lead wires, finger clips for GSR, three 6-packs of disposable electrodes for EMG and EKG, manual, and a pack of kleenex.


WaveWare: WaveRider Windows Software

WaveRider Jr. Specifications

Warranty Information


Return Policy: 30 days with restocking fee

 

 WaveRider Jr. Specifications

 
     
  Power Supply: one 9 volt battery (not included)  
  Optical isolation on all data lines  
  Sampling Rate per channel: 128 Hz  
  FFT Frequency resolution: 1 Hz (FFT generated in WaveWare)  
   A/D Resolution: 8 bit  
  Common Mode Rejection Ratio: 100 dB minimum  
  High pass filter: .5 Hz  
  Low pass filter: 40 Hz -72 dB at 60Hz  
  Two independent low noise differential channels with eight gains each.  
  One channel of GSR with eight automatic offsets  
Specifications subject to change without notice.
     

RANGE

GAIN

FULL SCALE

RESOLUTION

 

 

 

millivolts

microVolts

 

1

 

973

2876.34

11.24

 

2

 

1794

1627.14

6.36

 

3

 

3495

872.59

3.41

 

4

 

6698

460.27

1.80

 

5

 

12760

244.93

0.96

 

6

 

24439

125.82

0.49

 

7

 

35238

90.58

0.35

 

8

 

63889

43.78

0.17

 

WaveWare:  WaveRider Windows Software

WaveWare provides a fast response to biological signals for effective feedback. Pleasant screens display data for easy comprehension. User-created windows process and output biological signals. Double-clicking on any window opens a dialog box that controls the processing and display characteristics of that window. Musical feedback responds with a single note, or a user-defined range of notes, instruments, and scales.

Pre-Programmed Protocols provide an easy entry path for the beginning user. Once familiar with the software, Processed Data Modes  can be used to design advanced user-specific protocols.

Export Capabilities

Export to Ascii creates a text file of off-line processed data.  The text file can be opened in a spreadsheet and will display the output from each general graph present in a configuration file.  Time resolution of the text file will be set to the finest time resolution of the collected data streams.

WaveRider DDE creates a live link between raw and processed data outputs, and user-created client applications.

Storage Capabilities
WaveWare stores raw data from each channel.
Notes may be included in each file. 
Storage size  is approximately .5 megabytes per channel per hour.

Export to ascii provides the ability to export and store processed data.

 

 



Registration Desk - Sign in for Questions, Comments & Other Info

 

New PLAY ATTENTION Edufeedback system - for Attention, Focus, Concentration, Active and Short Term Memory, Hyperactivity Reduction, Reading Comprehension - uses the same feedback science and technology perfected for NASA astronauts and US Air Force pilots. Time payment plan options available.
More Info...

Desiccants - Mol Sieve, Silica Gel - Excellent Quality and Lowest Prices on Quantity Purchases. More info...

REGISTRATION
DESK

PLEASE SIGN IN HERE
FOR QUESTIONS, COMMENTS,
AND FURTHER INFORMATION

We accept Discover, Visa, MasterCard, and American Express credit cards

Contact Information:

Allied Products/Biofeedback Instrument Corp.
255 W. 98th Street
New York, N.Y. 10025
Tel. (212) 222-5665 (5667 Fax)
Email: brotmanp@verizon.net